CORPORATE DESCRIPTION:
Headquartered in Louisville, Colorado, Thermo BioStar develops, manufactures, and markets rapid diagnostic tests for infectious diseases in the U.S. and select international markets. The company’s patented OIA® (Optical ImmunoAssay) technology provides tests with extremely high sensitivity and specificity. They are the most effective rapid testing technology in the world providing culture equivalence or better in minutes. Each OIA test is configured to capture a unique analyte target and amplify its presence by creating a visible blue spot. OIA utilizes a silicon chip surface to reduce background, optimize signal to noise, and provide lab quality results in minutes.
Thermo Biostar, Inc. is a division of Thermo Electron Corporation, a global leader in providing technology-based instruments, components, and systems that offer total solutions for markets ranging from life sciences to telecommunications to food, drug, and beverage production.
For product information, click on the appropriate link below (for MSDS information on any product, contact ThermoBioStar for specific information):
MAX OIA | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate | Strep A | 87880 | ----- | 87880 (moderate) | Optical Immunoassay |
30-60 μl | 5 minutes | Qualitative Positive/ Negative |
|
Back to top |
|||||||||
FLU OIA | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate | Influenza A and B |
87804 | ----- | ----- | Optical Immuno assay |
30-60 μl | 15 minutes | Qualitative Positive/ Negative |
|
Back to top |
|||||||||
RSV OIA | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate | Respiratory Syncytial Virus | 87420 | ----- | ----- | Optical Immunoassay |
30-60 μl | 15 minutes | Qualitative Positive/ Negative |
|
Back to top |
|||||||||
Acceava Mononucleosis | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate/ Waived |
Mononucleosis | 86308 (moderate) | ----- | ----- | Enzyme Immunoassay |
30-60 μl | 5 minutes | Qualitative Positive/ Negative |
|
Back to top |
|||||||||
Acceava Group A Strep | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Waived | Strep A | ----- | ----- | ----- | Enzyme Immunoassay |
30-60 μl | 5 minutes | Qualitative Positive/ Negative |
|
Back to top |
|||||||||
Cd TOX A OIA | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate | Clostridium difficile A | 87803 | ----- | ----- | Optical Immunoassay |
30-60 μl | 10 minutes | Qualitative Positive/ Negative |
|
Back to top |
|||||||||
Chlamydia OIA | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate | Chlamydia | 87810 | ----- | ----- | Optical Immunoassay |
30-60 μl | 20 minutes | Qualitative Positive/ Negative |
|
Back to top |
|||||||||
Strep B OIA | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate | Group B Strep | 87802 | ----- | ----- | Optical Immunoassay |
250 μl | 28 minutes | Qualitative Positive/ Negative |
|
Back to top |
|||||||||
Acceava hCG Combo | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate/ Waived |
Pregnancy | 84703 | QW | ----- | Enzyme Immunoassay | 135 μl |
4 min. for Urine; 5-7
min. for Serum (depending on sensitivity |
Qualitative Positive/ Negative |
|
Back to top |
|||||||||
Acceava hCG MidStream | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Waived | Pregnancy | 81025 | ----- | ----- | Enzyme Immunoassay | 30-60 μl |
5 minutes |
Qualitative Positive/ Negative |
|
Back to top |
|||||||||
Acceava hCG Basic | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Waived | Pregnancy | 81025 | ----- | ----- | Enzyme Immunoassay | 30-60 μl |
5 minutes |
Qualitative Positive/ Negative |
|
Back to top |
|||||||||
ImmunoSTAT! Rotavirus | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Moderate | Rotavirus | 87425 | ----- | ----- | Enzyme Immunoassay | 25 μl |
10 minutes |
Qualitative Positive/ Negative |
|
Back to top |
|||||||||
PocketChem UA and Aution Sticks 10TA | |||||||||
CLIA Class. | Analytes performed | CPT Code for each analyte | 86308 QW (waived) | 87880 QW (waived) | Test method | Sample volume | Result time | Units the test is reported | |
Pending | Blood,
Glucose, Ketones, Bilirubin, Urobilinogen, Proteins, pH, Leukocytes, Specific Gravity, Nitrites |
81001, 81003 | ----- | ----- | Enzyme Immunoassay | 25 μl |
1 minute |
Semi- quantitative Normal/ Abnormal |
|
Back to top |
|||||||||
PocketChem UA | |||||||||
Test Menu
Features
Software information requirements
QC features
Reporting features
Up to 5 screen
captures which show examples of software:
see our website for a full animated view of PocketChem
www.thermobiostar.com |
|||||||||
Size & Weight | Y2K Compliant | Features | Data transfer capability | Operating System capability | Units
test result reported |
Instrument Management | LIS Interface capability | ||
9”x5”x1” 1.5
lbs |
Yes Contact ThermoBioStar for information | Reflectance
specto- photometer |
RS232 Cable Interface and Uni-Directional | mg/dl, +++,
mg/dl, +n, mmol/l,+++, mmol/l,+n |
Routine daily
cleaning of the Test Strip |
In development |
Back to top |